2. INSTALLATION

2.3.4Adjusting for orientation error

It may be impossible to perfectly align the processor unit on the fore-and-aft or port-and-starboard line. Open the top cover, loosen the two fixing screws on the angular rate sensor and turn. For example, if the orientation error is 2.5° to port, rotate the sensor 2.5° starboard. The range of adjustment is -45°to +45°. Close the top cover after completing the adjustment.

Fore-aft line or Port-starboard

direction

Reference

Direction

Processor Unit

Alignment hole on processor unit

Scale, every 2.5￿

Bulkhead Mounting

Plate

Fixing Screw

Angular rate sensor, top view

2.4Installing the Display Unit

2.4.1Desktop, overhead mounting

1.Fasten the hanger to the mounting location with four tapping screws (supplied). See the outline drawing for mounting dimensions.

2.Screw the knobs into the display unit.

3.Set display unit to the hanger and tighten the knobs.

4.Run the ground wire between the ground terminal on the display unit and the ship’s superstructure.

DesktopOverhead

Display unit mounting methods