7.0) TYPICAL LAYOUTS – PTU / PTS Series
10FT.
SYSTEM
50 FT.
SYSTEM
20 FT.
SYSTEM
30 FT.
SYSTEM
60 FT.
SYSTEM
40 FT.
SYSTEM
LEGEND |
| 70 FT. |
|
| |
Burner Box | 5 FT. Body Section | SYSTEM |
Flue Termination | 90 Deg. Elbow |
|
10 FT. Body Section | 180 Deg. |
|
| EMITTER LENGTH |
| BODY LENGTH | ||
MODEL | Min. | Max. | MODEL | Min. | Max. |
PTS 40/25 | 10 Ft. | 20 Ft. | PTU 40/25 | 10 Ft. | 10 Ft. |
|
|
|
|
|
|
PTS 50/30 | 20 Ft | 30 Ft. | PTU 50/30 | 10 Ft. | 15 Ft. |
|
|
|
|
|
|
PTS 75/50 | 20 Ft. | 30 Ft. | PTU 75/50 | 10 Ft. | 15 Ft |
|
|
|
|
|
|
PTS 100/65 | 30 Ft. | 40 Ft. | PTU 100/65 | 15 Ft. | 20 Ft. |
|
|
|
|
|
|
PTS 125/80 | 30 Ft | 50 Ft. | PTU 125/80 | 15 Ft. | 25 Ft. |
|
|
|
|
|
|
PTS 150/100 | 40 Ft. | 60 Ft. | PTU 150/100 | 20 Ft. | 30 Ft. |
|
|
|
|
|
|
PTS 175/110 | 50 Ft. | 70 Ft. | PTU 175/110 | 25 Ft. | 35 Ft. |
|
|
|
|
|
|
PTS 200/125 | 50 Ft. | 70 Ft. | PTU 200/125 | 25 Ft. | 35 Ft. |
|
|
|
|
|
|
NOTES:
1)In all configurations, the control unit must be connected directly to either a) the
2)Joining of two 90º elbows directly together to form a “Z” shape IS NOT permitted.
3)PTS / U 175/110 - 40 ft length available for special applications.
4)5 Ft. Body Packages may be utilized on any of these heaters to yield heater lengths from 15 ft. to 70 ft.
5)Any configuration of components not shown in the illustrations may be used except as noted in 1 and 2
Form #43343530 |
|
July 08 |