23.2) REMOVAL OF GAS VALVE AND MANIFOLD ASSEMBLY

Step 1

Step 3

Remove side access panel.

Open hinged access panel and disconnect wires from gas valve.

Step 2

Step 4

Loosen screws from manifold clamp and burner assembly.

Remove (6) screws from end panel. Rotate gas valve and manifold assembly slightly counter-clockwise and slide out from housing.

23.3) AIR SWITCH PRESSURE CHECK

Air

Connector

Switch

Tees

P1

+

P2

P1

P2

-

+

-

 

 

Temporary 1/4” ID Silicone /

-

+

0.65” WC

plastic tubing for pressure

 

Digital or Inclined

test.

 

 

 

Water Manometer

scale 0-2”w.c.

Common “C”

Normally open “NO”

1.Open hinged access panel.

2.Add tubing to connect the air switch tubing P1 + and P2 - with the connector tees and the probes P1+ and P2+.

Form #43343530

 

July 08

–47–

Page 48
Image 48