3

Installation Procedures

1.Make a cut-out (corresponding to size of the particular unit) in the switchgear panels or cabinet doors (see Figures 3-1 through 3-3).

2.Insert the unit into this cut-out from the front.

3.Insert the mounting screws together with mounting blocks in the slots provided in the metal cover and tighten all screws evenly until the surround panel covers the cut-out securely. Maximum torque is 0.25 N-m (2.2 lbf-in).

Caution

Over tightening the screws will cause irreparable damage to the front panel and break the touch screen itself.

Connect the provided power cord to the AC power supply. If additional grounding to a grounding screw is desired, use 14 AWG gauge wire minimum.

Table 3-1. Critical Dimensions for Installation

Dimension

IC5002

IC5005

IC5008

 

BC5002

BC5005

BC5008

 

 

 

 

Cover (W x H)

313 x 252mm

373.6 x 295.6 mm

426 x 355mm

 

23.3 x 9.9 in.

14.7 x 11.6 in.

16.8 x 14.0 in.

Cutout (recess) (W x

318 x 256mm +1.0mm

376 x 299mm +1.0mm

428 x 358mm +1.0mm

H)

12.5 x 10.1 in. + 0.04

14.8 x 11.8 in. + 0.04

16.9 x 14.0 in. + 0.04

 

in.

in.

in.

Space required for

Minimum 50mm (2 in) clearance at top and bottom of the unit. Minimum

ventilation

30mm (1.2 in.) at sides.

 

 

 

Note additional side space consideration is required for models with CD-

 

ROM, depending on cabinet design. Viewed from the front, there must be

 

sufficient space (132 mm or 5.20 in. minimum) to the left of the units to

 

allow the CD-ROM drive drawer to open.

 

Mounting depth

177mm

150mm

154mm

 

6.97 in.

5.9 in.

6.1 in.

3-2

Intelligence Panel PC User’s Manual – August 2003

GFK-2023C