Chapter

4

Installing Plug-in Modules

PCI bus or ISA bus plug-in modules, such as network or field bus cards, can be installed in the Intelligence Panel. The plug-in slots are accessed by removing the rear cover, which is secured by cross-head screws.

Avoiding Electrostatic Discharges

Caution

The components in Intelligence Panel PCs are susceptible to electrostatic discharge (ESD) and can be functionally damaged by incorrect handling. The same applies to plug-in modules. It is therefore vital that suitable precautionary measures are taken to avoid electrostatic discharges on contact with the components.

1.Before touching components or modules, always touch a metal object with a conductive surface that is connected to ground potential.

2.Wear a wrist strap.

3.When handling modules, only touch the edges or the module bracket, not the components themselves.

Installing Additional Modules

Caution

To avoid a risk of electric shock, turn off power to the industrial computer and disconnect the power supply before removing the rear panel.

1.Switch off the Intelligence Panel and all units connected to the PC and disconnect the PC from the power source.

2.Remove the screws from the rear panel and pick up the cover carefully.

GFK-2023C

4-1

Page 23
Image 23
GE BC5002, IC5002, BC5005, IC5005, IC5008, BC5008 user manual Avoiding Electrostatic Discharges, Installing Additional Modules