Micro 30 Secs

My Recipes

Microwaving

 

Advantium Oven

Press MICRO 30 SECS repeatedly for

The power level is automatically set at

30 second increments of microwave

high, but you can change it for more

cooking time. Oven starts immediately.

flexibility. See Microwave power levels

 

section for instructions.

See the MY RECIPE sections in the

 

Speedcook section of this book for

 

instructions on how to save, use,

 

change or delete a microwave custom

 

recipe.

 

Defrosting tips

Defrost by time

 

O

SEL

 

 

N T

 

 

UR

 

EC

 

T

 

 

T

 

PR

 

E

 

ESS TO ENT

R

 

 

 

 

 

CONTROL LOCK

 

 

 

 

HOLD 3 SECS

SPEED

CONV

 

MICRO

COOK

BAKE

 

WAVE

SETTINGS

COOKING

 

MICRO

OPTIONS

 

30 SECS

TIMER SURFACE VENT

ON/OFF LIGHT

PRESS TO TURN

TIMER OFF

Use DEFROST BY FOOD TYPE for meat, poultry, fish, and bread. Use DEFROST BY TIME for most other frozen foods.

nFoods frozen in paper or plastic can be defrosted in the package when using DEFROST BY TIME. Meats should be taken out of the package when using DEFROST BY FOOD TYPE. Closed packages should be slit, pierced or vented after food has partially defrosted. Plastic storage containers should be partially uncovered.

nFamily-size, prepackaged frozen dinners can be defrosted and microwaved. If the food is in a foil container, transfer it to a microwave-safe dish.

Use DEFROST BY TIME to defrost for a selected length of time.

1.Press the MICROWAVE pad.

2.Turn the selector dial to DEFROST. Press the dial to enter.

3.Turn the dial to DEFROST BY TIME. Press the dial to enter.

4.Turn the dial to select the time you want. Press the dial to enter.

5.Press the dial or START/PAUSE pad to start defrosting.

6.Turn the food over when the oven signals TURN FOOD OVER.

nFoods that spoil easily should not be allowed to sit out for more than one hour after defrosting. Room temperature promotes the growth of harmful bacteria.

nWhen defrosted, food should be cool but softened in all areas.

If still slightly icy, return to the microwave very briefly, or let it stand a few minutes.

nWhen defrosting 3 or more pounds of ground or cubed meat, remove defrosted portions at the turn signals.

Power level is automatically set

at 3, but can be changed. To change the power levels, see Microwave power levels for instructions.

You can defrost small items quickly by raising the power level after entering the time. Power level 7 cuts the total defrosting time in about half; power level 10 cuts the total time to about 1/3. When defrosting at high power levels, food will need more frequent attention than usual and may have some cooking.

25

Page 25
Image 25
GE ZSA2201 owner manual Micro 30 Secs My Recipes, Defrosting tips Defrost by time, Press Micro 30 Secs repeatedly for

ZSA2201 specifications

The GE ZSA2201 is a high-performance analog-to-digital converter that has garnered attention for its impressive features and capabilities, making it ideal for a variety of applications. This device is particularly sought after in industries such as telecommunications, instrumentation, and medical equipment, where precise data acquisition is critical.

One of the standout features of the GE ZSA2201 is its resolution, which can reach up to 24 bits. This high resolution allows the device to capture extremely subtle changes in voltage levels, providing users with the ability to measure signals with unparalleled accuracy. The converter's sampling rate is also noteworthy, supporting rates up to 1 MSPS (million samples per second). This enables the GE ZSA2201 to handle fast-changing signals, making it suitable for high-speed applications.

In terms of technologies, the ZSA2201 utilizes sophisticated delta-sigma modulation, which enhances its performance by reducing noise and improving the signal-to-noise ratio. This technology is essential for applications that require high fidelity in signal representation. The converter supports various input voltage ranges, making it versatile for different measurement scenarios. Users can easily configure it to suit their specific application needs, whether it be low-voltage or higher voltage environments.

The device is designed with integrated features that facilitate easy interfacing and communication. It supports standard digital communication protocols such as SPI (Serial Peripheral Interface), ensuring compatibility with a range of microcontrollers and other digital systems. This ease of integration simplifies the design process and reduces development time for engineers.

Moreover, the GE ZSA2201 is built to operate effectively across a wide temperature range, making it reliable in diverse environmental conditions. Its packaging is also designed to endure the rigors of industrial settings, ensuring robustness and longevity.

Finally, the GE ZSA2201 exemplifies a commitment to energy efficiency, with a low power consumption profile that contributes to longer operational life in battery-powered applications. In summary, the GE ZSA2201 is a versatile and high-performance analog-to-digital converter that excels in accuracy, speed, and reliability, making it a top choice for engineers looking to enhance their data acquisition systems.