Setup
3.Electrical requirements See table 1.
Installing this equipment requires access to parts which may cause electric shock or other serious injury if work is not performed properly. Have a qualified electrician connect power and ground to main power switch terminals, see step 3. Be sure your installation complies with all National, State and Local safety and fire codes.
Table 1: Electrical Requirements (kW/Full Load
Amps)
|
|
| Full |
|
|
|
| Load |
|
|
| Voltage | Peak | System |
Part | Model | (phase) | Amps* | Watts** |
|
|
|
|
|
256886 | 230V (3) | 71 | 26,600 | |
|
|
|
|
|
256887 | 400V (3) | 41 | 26,600 | |
|
|
|
|
|
*Full load amps with all devices operating at maxi- mum capabilities. Fuse requirements at various flow rates, ratios, and mix chamber sizes may be less.
**Total system watts, based on maximum hose length for each unit, 410 ft (125 m) including whip hose.
4.Connect electrical cord
NOTE:
Power cord is not suppled. See table 2.
Table 2: Power Cord Requirements
|
| Cord Specification | |
Part | Model | AWG (mm2) | |
256886 | 4 | (21.2), 3 wire + ground | |
|
|
|
|
256887 | 8 | (8.4), 4 wire + ground | |
|
|
|
|
a.230V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect green to ground (GND).
GND
L1
L2
ti2515b
b.400V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND).
GND
L1
L2
L3
ti3248b
NOTE:
The motor must rotate