Startup

j.Manual current control mode only:

When in manual current control mode, monitor hose temperature with thermometer. Install per instructions below. Thermometer reading must not exceed 160°F (71°C). Never leave machine unattended when in manual current control mode.

If FTS is disconnected or display shows diag- nostic code E04, turn main power switch OFF

then ON

to clear diagnostic

code and enter manual current control mode.

display will show current to hose. Current

is not limited by target temperature.

To prevent overheating, install hose thermome- ter close to gun end, within operator view. Insert thermometer through foam cover of A compo- nent hose so stem is next to inner tube. Ther- mometer reading will be about 20°F less than actual fluid temperature.

If thermometer reading exceeds 160°F (71°C),

reduce current with key.

4.Set pressure

ON / OFF

PARK

PSI

BAR

Motor Controls and Indicators, see page 15

a.Press to display the pressure reading.

b.Press motor . Motor and pumps start. Display shows system pressure.

NOTE:

Motor must rotate counterclockwise when viewed from shaft end. See Connect electrical cord, page 18.

c.Adjust hydraulic pressure control until display shows desired fluid pressure.

+-

ti7731ati7732a

NOTICE

Never adjust hydraulic pressure while spraying. This will result in over pressure alarm E23.

NOTE:

If display pressure is greater than desired pressure, reduce the hydraulic pressure and trigger gun to reduce pressure.

26

313539F

Page 26