Startup

2.Load fluid with feed pumps

NOTE:

The Reactor is tested with oil at the factory. Flush out the oil with a compatible solvent before spraying. See page 38.

a.Check that all Setup steps are complete.

b.Turn on component B agitator, if used.

c.Turn both PRESSURE RELIEF/SPRAY valves

(SA, SB) to SPRAY

.

SA

SB

ti9877a

d.Start feed pumps.

e.Open fluid inlet valves (FV). Check for leaks.

FV

ti10972a

Do not mix components A and B during startup. Always provide two grounded waste containers to keep component A and component B fluids separate.

f.Use feed pumps to load system. Hold gun fluid manifold over two grounded waste containers.

Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.

ti2484a

24

313539F

Page 24
Image 24
Graco 313539F important safety instructions Load fluid with feed pumps