Technical Data

Technical Data

Category

Data

Maximum Fluid Working Pressure

3500 psi (24.1 MPa, 241 bar)

Fluid Inlets

3/4 npsm union in 1 in. npt(f) ball valve

Fluid Outlets

Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter

 

Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter

Fluid Circulation Ports

1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum

Maximum Fluid Temperature

190°F (88°C)

Maximum Output (10 weight oil at

Model H-VR: 3.0 gpm (11.4 liter/min) (60 Hz)

ambient temperature) 1:1

 

Output per Cycle

Variable: 2 oz.- 5 oz. (60 cc - 150 cc) per pump*

Stroke Length

Variable: 2 in. - 5 in. (5.08 cm - 12.7 cm)

Line Voltage Requirement

230V 3 phase units: 195-264 Vac, 50/60 Hz

 

400V 3 phase units: 338-457 Vac, 50/60 Hz

Amperage Requirement

See Models, page 2.

Heater Power

See Models, page 2.

(A and B heaters total, no hose)

 

Hydraulic reservoir capacity

3.5 gal. (13.6 liters)

Recommended hydraulic fluid

Citgo A/W Hydraulic Oil, ISO Grade 46

Sound power, per ISO 9614-2

90.9 dB(A)

Sound pressure,

84.0 dB(A)

1 m from equipment

 

Weight

955 lb (433 kg)

Wetted Parts

Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,

 

fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically

 

resistant o-rings

*Output example: 2.5:1 ratio = 150 cc (B side):60 cc (A side)

2.5:1 output = 150 cc (B side) + 60 cc (A side) = 210 cc per cycle