Standby
Standby
If you stop spraying for a period of time, the unit will enter standby by shutting down the electric motor and hydraulic pump, to reduce equipment wear and mini- mize heat buildup. The ON/OFF LED and the pres- sure/cycle display on the motor control panel will flash when in standby.
NOTE: |
|
The A , B , and | heat zones will not be |
shut off in standby. |
|
To restart, spray off target for 2 sec. The system will sense the pressure drop and the motor will ramp up to full speed in a few seconds.
NOTE:
This feature is disabled from the factory.
To activate or disable standby, adjust DIP switch #3 on the motor control board. See Reactor
The idle time before entering standby is
1. Turn main power switch OFF | . |
2. Press and hold , then turn main power switch
ON .
3.Press or
to select desired timer set- ting
4. Turn main power switch OFF | to save |
changes.
Shutdown
1. Shut off A , B , and | heat zones. |
2.Park pumps.
a.Press .
b.Trigger gun until pump A stops in the retracted position and the pressure of both pumps bleeds down.
3. Turn main power OFF | . |
4. Close both fluid supply valves (FV).
FV
ti10971a
5. Relieve pressure, page 31.
30 | 313539F |