Maintenance
Maintenance
•Inspect hydraulic and fluid lines for leaks daily.
•Clean up all hydraulic leaks; identify and repair cause of leak.
•Inspect fluid inlet strainer screens daily, see below.
•Grease circulation valves weekly with Fusion grease (117773).
ti9879a
•Check hydraulic fluid level weekly. Check hydraulic fluid level on dipstick (DS). Fluid level must be between indent marks (IM) on dipstick. Refill as required with approved hydraulic fluid; see Techni- cal Data on page 40 and the Approved
DS
IM
ti10003a
ti7861a
•Change
Table 5: Frequency of Oil Changes
Ambient | Recommended |
Temperature | Frequency |
|
|
|
|
0 to 90°F | 1000 hours or 12 months, |
whichever comes first | |
|
|
90°F and above | 500 hours or 6 months, |
(32°C and above) | whichever comes first |
|
|
•Keep component A from exposure to moisture in atmosphere, to prevent crystallization.
•Clean gun mix chamber ports regularly. See gun manual.
•Clean gun check valve screens regularly. See gun manual.
•Use compressed air to prevent dust buildup on con- trol boards, fan, motor (under shield), and hydraulic oil coolers.
•Keep vent holes on bottom of electrical cabinet open.
36 | 313539F |