Setup

8.Connect heated hose

NOTE:

See Heated Hose manual 309572 for detailed instruc- tions on connecting heated hoses.

NOTE:

If spraying at a ratio other than 1:1, an E24 may occur. Size hoses and mix chamber appropriately to avoid pressure imbalance.

NOTICE

The fluid temperature sensor (C) and whip hose (D) must be used with heated hose, see page 19. Hose length, including whip hose, must be 60 ft (18.3 m) minimum.

a. Turn main power OFF

.

b.Assemble heated hose sections, FTS, and whip hose.

c.Connect A and B hoses to A and B outlets on Reactor fluid manifold (FM). Hoses are color coded: red for component A (ISO), blue for com- ponent B (RES). Fittings are sized to prevent connection errors.

FM

N

A

P

B

ti9878a

NOTE:

Manifold hose adapters (N, P) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose.

d.Connect cables (Y). Connect electrical connec- tors (V). Be sure cables have slack when hose

bends. Wrap cable and electrical connections with electrical tape.

Y

V

ti9881a

9.Close gun fluid manifold valves A and B

ti2411a

10.Connect whip hose to gun fluid manifold

Do not connect manifold to gun.

ti2417a

11.Pressure check hose

See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.

20

313539F

Page 20
Image 20