c.400V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND).

GND

L1

L3

L2 N

ti2725a

Some 3-phase models utilize a 3-phase motor. The motor must rotate counter- clockwise when viewed from shaft end. To reverse rotation, disconnect power and reverse power leads L1 and L2.

5.Connect feed pumps

a.Install feed pumps (K) in component A and B supply drums. See FIG. 1 and FIG. 2, pages 14 and 15.

A minimum feed pressure of 50 psi (0.35 MPa, 3.5 bar) is required at both feed inlet pressure gauges (FP). Maxi- mum feed pressure is 250 psi (1.75 MPa, 17.5 bar). Maintain A and B feed pressures within 10% of each other.

FP

ti10006a

b.Seal component A drum and use desic- cant dryer (M) in vent.

Setup

c.Install agitator (L) in component B drum, if necessary.

d.Ensure A and B inlet valves (FV) are closed.

FV

ti9883a

Supply hoses from feed pumps should be 3/4 in. (19 mm) ID.