6. Connect pressure relief lines

Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpres-

sure relief valves when set to SPRAY .

Lines must be open so valves can automati- cally relieve pressure when machine is oper- ating.

If circulating fluid back to the supply drums, use high pressure hose rated to withstand the maximum working pressure of this equipment.

a.Recommended: Connect high pressure hose (R) to relief fittings (BA, BB) of both PRESSURE RELIEF/SPRAY valves, Route hose back to component A and B drums. See FIG. 1, page 14.

SB

SA

R

BA

R

BBti9880a

b.Alternately: Secure supplied bleed tubes (N) in grounded, sealed waste containers (H). See FIG. 2, page 15.

7.Install Fluid Temperature Sensor (FTS)

The Fluid Temperature Sensor (FTS) is sup- plied. Install FTS between main hose and whip hose. See Heated Hose manual 309572 for instructions.