Standby

Standby

If you stop spraying for a period of time, the unit will enter standby by shutting down the electric motor and hydraulic pump, to reduce equipment wear and minimize heat buildup. The ON/OFF LED and the pressure/cycle dis- play on the motor control panel will flash when in standby.

The A , B , and heat zones

will not be shut off in standby.

To restart, spray off target for 2 sec. The sys- tem will sense the pressure drop and the motor will ramp up to full speed in a few seconds.

This feature is disabled from the factory.

To activate or disable standby, adjust DIP switch #3 on the motor control board. See Reactor Repair-Parts manual 312063.

The idle time before entering standby is user-settable as follows:

1. Turn main power switch OFF

.

2. Press and hold , then turn main power

switch ON

.

3.Press or to select desired timer setting (5-20, in 5 minute increments). This sets the length of inactive time before the unit will enter standby.

4. Turn main power switch OFF

to

save changes.