Startup
Do not mix components A and B during startup. Always provide two grounded waste containers to keep component A and compo- nent B fluids separate.
h.Use feed pumps to load system. Hold gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean,
ti2484a
8. Set temperatures
A
B
°F
°C
Temperature Controls and Indicators, see page 18
This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To avoid severe burns:
•Do not touch hot fluid or equipment.
•Allow equipment to cool completely before touching it.
•Wear gloves if fluid temperature exceeds 110°F (43°C).
a. Turn main power ON | . |
b. Press °F or °C to change tem-
perature scale.
c.Press to display target tempera- tures.
d. To set A heat zone target tempera-
ture, press or until display
shows desired temperature. Repeat for
Band zones.
For zone only, if FTS is discon-
nected at startup, display will show hose current (0A). See step j, page 32.
312062W | 31 |