8. Connect heated hose

See Heated Hose manual 309572 for detailed instructions on connecting heated hoses.

The fluid temperature sensor (C) and whip hose (D) must be used with heated hose, see page 27. Hose length, including whip hose, must be 60 ft (18.3 m) minimum.

a. Turn main power OFF

.

b.Assemble heated hose sections, FTS, and whip hose.

c.Connect A and B hoses to A and B out- lets on Reactor fluid manifold (FM). Hoses are color coded: red for compo- nent A (ISO), blue for component B (RES). Fittings are sized to prevent con- nection errors.

FM

N

A

P

B

ti9878a

Manifold hose adapters (N, P) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose.

Setup

d.Connect cables (Y). Connect electrical connectors (V). Be sure cables have slack when hose bends. Wrap cable and electrical connections with electri- cal tape.

Y

V

ti9881a

9. Close gun fluid manifold valves A and B

ti2411a

10.Connect whip hose to gun fluid mani- fold

Do not connect manifold to gun.

ti2417a

11. Pressure check hose

See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.

28

312062W

Page 28
Image 28
Graco H40, H50, H25 Connect heated hose, Close gun fluid manifold valves a and B, Connect whip hose to gun fluid mani- fold