Models

H-XP2 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approximate

 

 

 

Maximum Fluid

 

Full Load

 

 

 

Primary

 

Max Flow

 

Output per

 

Hydraulic

 

Working

 

Peak Amps*

Voltage

System

 

Heater

 

Rate

 

Cycle (A+B)

 

Pressure

 

Pressure

Part, Series

Per Phase

(phase)

Watts†

 

Watts

 

gpm (lpm)

 

gal. (liter)

 

Ratio

 

psi (MPa, bar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

255403, F

100

230V (1)

23,260

15,300

1.5 (5.7)

0.042 (0.16)

2.79:1

3500 (24.1, 241)

255404, F

59

230V (3)

23,260

15,300

1.5 (5.7)

0.042 (0.16)

2.79:1

3500 (24.1, 241)

255405, F

35

400V (3)

23,260

15,300

1.5 (5.7)

0.042 (0.16)

2.79:1

3500 (24.1, 241)

H-XP3 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approximate

 

 

 

Maximum Fluid

 

Full Load

 

 

 

Primary

 

Max Flow

 

Output per

 

Hydraulic

 

Working

 

Peak Amps*

Voltage

System

 

Heater

 

Rate

 

Cycle (A+B)

 

Pressure

 

Pressure

Part, Series

Per Phase

(phase)

Watts†

 

Watts

 

gpm (lpm)

 

gal. (liter)

 

Ratio

 

psi (MPa, bar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

253403, E

100

230V (1)

23,100

 

12,000

 

2.8 (10.6)

 

0.042 (0.16)

 

2.79:1

 

3500 (24.1, 241)

253404, E

95

230V (3)

31,700

 

20,400

 

2.8 (10.6)

 

0.042 (0.16)

 

2.79:1

 

3500 (24.1, 241)

253405, E

52

400V (3)

31,700

 

20,400

 

2.8 (10.6)

 

0.042 (0.16)

 

2.79:1

 

3500 (24.1, 241)

*Full load amps with all devices operating at maximum capabilities. Fuse requirements at vari- ous flow rates and mix chamber sizes may be less.

Total system watts, based on maximum hose length for each unit:

Parts 255400 through 255408, 310 ft (94.6 m) maximum heated hose length, including whip hose.

Parts 253400 through 253408, 253725 through 253727, 256505, and 256506, 410 ft (125 m) maximum heated hose length, including whip hose.

Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum flow.

CE approval does not apply.

Approvals:



#ONFORMS TO !.3)5, 3TD  #ERTIFIED TO #!.#3!3TD

#.O 

6

312062W

Page 6