Alarm Troubleshooting
Table 17. Alarm Troubleshooting
E-7: DOSE TIME A ALARM and E-8: DOSE TIME B ALARM
Cause | Solution |
|
|
System is in Mix mode and gun is only partially triggered, | Fully trigger the gun. |
allowing air but no fluid to pass through gun. |
|
|
|
Fluid flow rate is too low. | Increase flow rate. |
|
|
Dose time setting is too short for the current flow rate. | Increase the dose time setting. |
|
|
Flow meter or cable failed or flow meter clogged. | To check meter sensor operation, remove meter cap to |
| expose sensor. Pass a ferrous metal tool in front of the |
| sensor. |
TI12792a
| If there is a meter or cable failure, you will see a large dif- |
| ference between the amount of fluid dispensed and the |
| flow meter volume displayed by the EasyKey. Clean or |
| repair meter as necessary. Also see meter manual |
| 308778. |
| Follow Meter Calibration procedure, page 100. |
|
|
Slow actuation of component A or B valves. | See |
| ALARM, pages |
|
|
The supply pump is not turned on. | Turn on the supply pump. |
|
|
System is in Mix mode with 0 volume entered for Min | Verify condition of fuse and replace if necessary. See |
Material Fill Volume (see Option Screen 1, page 36), | |
and Fuse F1 is blown. |
|