NOTE: Each screen displays the current screen number and the total number of screens in the group. The total number of screens in a group and the fields displayed on each screen may vary depending on selections made in the System Configuration Screens and Option Screens.
Advanced Setup Screen 1
FIG. 40. Advanced Setup Screen 1
Flow Control Override
This field only appears if Flow Control is set to “On” in Configure Screen 5 on page 34, and Manual Override is set to “On” (see below). The selections made will affect the display in Manual Override Screen on page
25. Choose the desired selection as defined below:
| Selection | Description |
|
|
|
|
|
| Off | Normal operation |
|
|
|
|
|
| % Open | Flow control regulator is opened to a |
|
|
| desired percentage. |
|
|
|
|
|
| Pressure | Flow control regulator is opened to a |
|
|
| calibrated pressure. |
|
|
|
|
|
|
|
|
|
|
|
|
|
FIG. 41. Flow Control Override Menu
Setup Mode
Manual Override
This field only appears if Run Mode is set to “Automatic” or
Gun 1/Gun2 Potlife Volume
Enter the potlife volume (1 to 1999 cc) for each gun. This is the amount of material required to move through the mix manifold, hose and applicator/gun before the potlife timer is reset.
Use the following information to determine approximate pot life volume (PLV) in cc:
Hose ID (inches) | Volume (cc/foot)* |
|
|
3/16 | 5.43 |
1/4 | 9.648 |
|
|
3/8 | 21.71 |
|
|
Integrator manifold and mixer volume = 75 cc Spray Gun Volume = 20 cc
(Hose Volume* x Feet of Hose) + 75 + 20 = PLV
Color/Catalyst Purge
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 36. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.
Color/Catalyst Fill
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 36. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.