Graco TI12553a, TI12552a important safety instructions Advanced Setup Screen

Models: TI12553a TI12552a

1 134
Download 134 pages 19.13 Kb
Page 39
Image 39

NOTE: Each screen displays the current screen number and the total number of screens in the group. The total number of screens in a group and the fields displayed on each screen may vary depending on selections made in the System Configuration Screens and Option Screens.

Advanced Setup Screen 1

FIG. 40. Advanced Setup Screen 1

Flow Control Override

This field only appears if Flow Control is set to “On” in Configure Screen 5 on page 34, and Manual Override is set to “On” (see below). The selections made will affect the display in Manual Override Screen on page

25. Choose the desired selection as defined below:

 

Selection

Description

 

 

 

 

 

 

Off

Normal operation

 

 

 

 

 

 

% Open

Flow control regulator is opened to a

 

 

 

desired percentage.

 

 

 

 

 

 

Pressure

Flow control regulator is opened to a

 

 

 

calibrated pressure.

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 41. Flow Control Override Menu

Setup Mode

Manual Override

This field only appears if Run Mode is set to “Automatic” or “Semi-automatic” in Configure Screen 3, page 33. Set to “On” to override all outside control. If selected, the Manual Override Screen (page 25) will be added, and the Flow Control Override field appears (see above).

Gun 1/Gun2 Potlife Volume

Enter the potlife volume (1 to 1999 cc) for each gun. This is the amount of material required to move through the mix manifold, hose and applicator/gun before the potlife timer is reset.

Use the following information to determine approximate pot life volume (PLV) in cc:

Hose ID (inches)

Volume (cc/foot)*

 

 

3/16

5.43

1/4

9.648

 

 

3/8

21.71

 

 

Integrator manifold and mixer volume = 75 cc Spray Gun Volume = 20 cc

(Hose Volume* x Feet of Hose) + 75 + 20 = PLV

Color/Catalyst Purge

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 36. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.

Color/Catalyst Fill

This field only appears if the system includes a color change module and Flush and Fill Input is set to “Global” in Option Screen 1, page 36. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.

312779E

39

Page 39
Image 39
Graco TI12553a, TI12552a important safety instructions Advanced Setup Screen