Setup Mode
NOTE: Each screen displays the current screen number and the total number of screens in the group. The total number of screens in a group and the fields displayed on each screen may vary depending on selections made in the System Configuration Screens and Option Screens.
Recipe Setup Screen 1
FIG. 50. Recipe Setup Screen 1
Ratio
Enter the mix ratio of component A over component B (0.0:1 to 50:1).
Ratio Tolerance
Enter the ratio tolerance (1 to 99%). This refers to the percent of acceptable variance that the system will allow before a ratio alarm occurs.
Component A (Color) Valve (if present)
This field only appears if the system includes a color change module. Enter the color valve number (1 to 30).
Component B (Catalyst) Valve (if present)
This field only appears if the system includes a color change module. Enter the catalyst valve number (1 to 4).
Recipe Setup Screen 2
FIG. 51. Recipe Setup Screen 2
Minimum Flush Volume
This field only appears if Flush Volume Check is set to “On” in Option Screen 1 on page 36. Enter the mini- mum flush volume (0 to 999 cc). Entering 0 disables this function.
Potlife Time
Enter the potlife time (0 to 999 minutes). Entering 0 dis- ables this function.
Color/Catalyst Purge
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Rec- ipe” in Option Screen 1, page 36. Enter the purge time (0 to 99 seconds). It refers to the amount of time required to flush the lines from the color or catalyst mod- ule to the dose valve or dump valve.
Color/Catalyst Fill
This field only appears if the system includes a color change module and Flush and Fill Input is set to “Rec- ipe” in Option Screen 1, page 36. Enter the fill time (0 to 99 seconds). It refers to the time required to fill the lines from the color or catalyst module to the dose valve or dump valve.