Alarm Troubleshooting

Table 17. Alarm Troubleshooting

E-12: CAN COMM ERROR ALARM

 

 

 

 

 

 

 

Cause

 

Solution

 

 

Communication between the Color Change Module and

• Verify that all cables are connected securely and that

the Fluid Station is interrupted.

the Color Change power LED turns on. If the power

 

LED does not turn on, the problem is probably

 

caused by a bad connection. The nut on the connec-

 

tor must make at least 5 complete turns to ensure a

 

good connection. If the power LED still does not

 

light, the cable or board is bad.

 

 

 

• Check the color change board DIP switch settings.

 

See the Installation manual.

 

 

 

• Check the fluid plate board DIP switch setting. An

 

incorrect setting will not cause E-12 alarms, but a

 

correct setting will help prevent E-12 caused by elec-

 

trical noise. See the Installation manual.

 

 

 

• Check EasyKey software version (displayed at power

 

up for all versions and when the lock key is pressed

 

for version 2.02.000 and above). If older than

 

1.06.002, upgrade. Be sure to save settings through

 

BWI or AWI before upgrading, as they will be erased.

 

 

 

• The sticker on the color change board shows the

 

software part number and version, for example

 

15T270

1.01. If the version is older than 1.01,

 

replace the board.

 

 

 

• If all software versions and DIP switch settings are

 

correct and you still have E-12 alarms, then the sys-

 

tem has a bad connection, bad cable, or bad circuit

 

board. Use a multimeter on the CAN connectors to

 

test whether there is a good connection between

 

systems. If there is, you have a bad circuit board. If

 

there is not, you have a bad connector, connection,

 

or cable.

 

 

 

Communication between the Color Change Module and

Verify condition of fuse and replace if necessary. See

the Fluid Station is interrupted. The fluid control board

Repair-Parts manual.

fuse is blown.

 

 

 

 

E-13: HIGH FLOW ALARM or E-14: LOW FLOW ALARM (may also be set as Warnings)

 

 

 

Cause

Solution

 

 

Fluid system is producing too much or too little flow.

Troubleshoot fluid system for restrictions, leaks,

 

exhausted fluid supply, incorrect settings, etc. Increase

 

or decrease flow rate, as required.