Setup Mode

DD Setup Mode

See FIG. 32 and FIG. 33. Selecting “DD” makes the Dynamic Dosing Setup mode field appear. Select On to enable DD setup mode, or Off to disable. See page 86 for further information.

FIG. 32. Configure Screen 4, dynamic dosing selected

FIG. 33. Configure Screen 4, dynamic dosing setup mode enabled

Dose Time Alarm

Enter the dose time (1 to 99 seconds). This is the amount of time allowed for a dose to occur before a dose time alarm occurs.

Number of Guns

This field only appears if Run Mode is set to “Manual” or Semi-Automatic” in Configure Screen 3, page 33. Enter the number of spray guns (1 or 2).

NOTE: Only 1 gun is used in automatic mode.

Gun Flush Box (manual or semi-automatic mode)

This field only appears if Run Mode is set to “Manual” or Semi-Automatic” in Configure Screen 3, page 33. Enter the number of gun flush boxes (Off, 1, or 2).

Configure Screen 5

FIG. 34. Configure Screen 5

Flow Control

This field only appears if Run Mode is set to “Automatic” in Configure Screen 3, page 33. Select On or Off.

If set to “On,” Advanced Setup Screen 5, page 41 is added.

Special Outputs

Select special outputs (0-4). Each output has two differ- ent start times and durations.

Solvent Monitor

Select solvent monitor (Off, Flow Switch, or Meter).

Web Browser IP

The default web browser IP address prefix is 192.168.178.__ Assign a unique number for each EasyKey in your system (1-99) and enter it here.