Setup Mode
DD Setup Mode
See FIG. 32 and FIG. 33. Selecting “DD” makes the Dynamic Dosing Setup mode field appear. Select On to enable DD setup mode, or Off to disable. See page 86 for further information.
FIG. 32. Configure Screen 4, dynamic dosing selected
FIG. 33. Configure Screen 4, dynamic dosing setup mode enabled
Dose Time Alarm
Enter the dose time (1 to 99 seconds). This is the amount of time allowed for a dose to occur before a dose time alarm occurs.
Number of Guns
This field only appears if Run Mode is set to “Manual” or
NOTE: Only 1 gun is used in automatic mode.
Gun Flush Box (manual or semi-automatic mode)
This field only appears if Run Mode is set to “Manual” or
Configure Screen 5
FIG. 34. Configure Screen 5
Flow Control
This field only appears if Run Mode is set to “Automatic” in Configure Screen 3, page 33. Select On or Off.
If set to “On,” Advanced Setup Screen 5, page 41 is added.
Special Outputs
Select special outputs
Solvent Monitor
Select solvent monitor (Off, Flow Switch, or Meter).
Web Browser IP
The default web browser IP address prefix is 192.168.178.__ Assign a unique number for each EasyKey in your system