Guns without Manifold
The gun is shipped ready for use in a circulat- ing system, with a fitting installed in each fluid port. Connect the fluid supply line to one fluid inlet fitting (15) and the fluid return line to the other.
To use the gun in a
1 Install for use in a
2 Use fitting (15) for use in a circulating system.
15
33 1 2
TI14430A
FIG. 2: Guns without Manifold
Ground System
The following grounding instructions are mini- mum requirements for a system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.
Installation
Pump/Fluid Supply
Ground the pump by connecting a ground wire and clamp between the fluid supply and a true earth ground as instructed in your separate pump instruction manual.
Air Compressors and Hydraulic Power Supplies
Ground the air compressors and hydraulic power supplies according to the manufacturer recommendations.
Spray Gun
Ground the spray gun by mounting the mani- fold to a properly grounded reciprocator, robot, or stationary mount. Check the electrical resis- tance between the manifold and a true earth ground. Resistance must not exceed
1 megohm.
Fluid Supply Container
Ground the fluid supply container according to local code.
Object Being Sprayed
Ground the object that is being sprayed according to local code.
Solvent Pails
Ground all solvent pails that are used when flushing according to local code. Use only con- ductive metal pails placed on a grounded sur- face. Do not place the pail on a
313869B | 11 |