Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

Gun spitting.

Air getting into paint stream.

Check if fluid source is empty

 

 

and fill.

 

 

Tighten fluid nozzle (4).

 

 

Check fluid nozzle o-ring (3) for

 

 

damage.

 

 

Check fluid nozzle (4) for dam-

 

 

age.

 

 

 

Will not spray.

Fluid control valve (11) turned

Adjust fluid control valve (11)

 

too far clockwise.

counterclockwise.

 

 

 

 

Fluid source empty.

Refill.

 

 

 

Excessive air blowing back.

Loose fluid nozzle (4).

Tighten fluid nozzle (4).

 

 

 

 

Damaged fluid nozzle seal (3).

Replace seal (3).

 

 

 

Gun fluid pressure is too high

Using needle/nozzle kit with

Use needle/nozzle kit with

with gun triggered (cannot

too small orifice.

larger orifice.

achieve desired flow rate).

 

 

 

 

 

Using a low fluid pressure set-

Using needle/nozzle kit with

Use needle/nozzle kit with

ting, the fluid flow is too high,

too large orifice.

smaller orifice.

making it necessary to restrict

 

 

needle travel to reduce fluid

 

 

flow.

 

 

 

 

 

Fluid system will not operate at

There is no fluid regulator, or

Add low pressure fluid regula-

low enough pressure [below

air regulator is not sensitive

tor, or add more sensitive low

10 psi (70 kPa, 0.7 bar)].

enough at low pressure.

pressure air regulator.

 

 

 

Fluid flow is fluttering while

Fluid source empty.

Refill.

spraying.

 

 

 

 

 

313869B

23

Page 23
Image 23