Connect Fluid Hose
NOTE:
•Before connecting the fluid line, blow it out with air and flush it with solvent. Use solvent that is compatible with the fluid to be sprayed.
•Install a fluid regulator (L) on the fluid line to control fluid pressure to the gun. See FIG. 8.
•Install a fluid shutoff valve (M) to shut off the fluid supply to the gun.
•Filter the fluid line of coarse particles and sediment to avoid clogging the fluid nozzle and causing finishing defects. Inline fluid filter 24B707 is available.
K
L
M
J
ti7016a
FIG. 8: Connect Fluid Hose.
1.Connect the fluid supply hose (J) to the gun fluid inlet (S), 6 mm OD tube fitting. See FIG. 9.
2.Connect the other end of the fluid hose (J) to a regulated fluid supply outlet (M).
3.In a circulating system, connect a grounded fluid return hose to the gun fluid outlet (T). See FIG. 9.
Setup
In a
KEY
N Cylinder Air Inlet: accepts 6 mm OD tubing
P Atomization Air Inlet: 6 mm OD tubing
R Fan Air Inlet: 6 mm OD tubing
S Fluid Inlet: 6 mm OD tubing
T Fluid Outlet (circulating gun only): 6 mm OD tubing
With Manifold
N
RP
T (or S) | S (or T) |
| TI14436A |
Without Manifold |
|
T (or S) | S (or T) |
PR
N
TI14437A
FIG. 9: Air and Fluid Ports
313869B | 15 |