Operation
Operation
Pressure Relief Procedure
1.Turn off all bleed type air valves and all other air and fluid supplies to the gun.
2.Trigger the gun into a grounded metal waste container to relieve fluid pressure.
ti8174a
FIG. 13: Pressure Relief
Apply Fluid
The gun does not have an air shutoff. The air should be activated before the fluid to ensure full atomization of fluid and prevent buildup on the air cap.
Adjust the system control device, if it is auto- matic, so the gun starts spraying just before meeting the part and stops as soon as the part has passed.
To achieve best results when applying fluid:
•Keep gun perpendicular and 6 to 8 in. (150 to 200 mm) from object being sprayed.
•Use smooth, parallel strokes across sur- face to be sprayed with 50% overlap.
Incorrect
TI14439A
Correct
TI14438A
FIG. 14: Correct Spray Method
18 | 313869B |