Winding Cutterhead

Guard

Though the cutterhead guard is pre-installed, you should check to make sure it works.

1.Pull the guard back and let it go. The guard should spring back over the cutterhead.

—If the guard drags across the table, loosen the set screws on the guard, raise it slight- ly, then tighten the set screws.

—If the guard does not spring back over the cutterhead, loosen the set screws on the jointer shown in Figure 10, hold the guard over the cutterhead, and wind the shaft collar clockwise. Tighten the set screws. Check to see if the guard works and adjust the collar as needed.

Shaft

Collar

Set

Screws

Figure 10. Loosening set screws.

G0609 12" Parallelogram Jointer

Pedestal Switch

The pedestal switch is upside down for shipping purposes.

Components and Hardware Needed:

Qty

• Flat Washers 10mm (Pedestal)

2

• Lock Washers 10mm (Pedestal)

2

Cap Screws M10-1.5 x 25 (Pedestal)

2

Pedestal Switch

1

To set up the pedestal switch:

1.Remove the M10-1.5 x 25 cap screws and flat washers shown in Figure 11.

2.Turn the pedestal upright and fasten it to the jointer with the cap screws and washers removed in Step 1, as shown in Figure 12.

Figure 11. Location of pedestal mounting

hardware (one side shown).

Figure 12. Mounting pedestal in upright position. -17-