Guardian Technologies 5308, 4582 & 4987, 4451 & 4986, 4583 manual = Idle Control Transformer Output

Models: 5308 4583 4451 & 4986 4582 & 4987

1 90
Download 90 pages 17.81 Kb
Page 27
Image 27

Section 4

ENGINE DC CONTROL SYSTEM

120V

120V

DUPLEX

GFCI

11B

11B

0

22

120/240V

120/240V

50A

30A

 

TWISTLOK

22

120V/30A

TWISTLOK

22

120V/30A

TWISTLOK

TEST

RESET

 

 

 

 

 

 

 

 

 

 

 

 

TEST

RESET

 

0

44A

11A

0

44B

0

11D

0

44D

22

0

11C

22

0

44C

C.B.

 

22

 

C.B.

 

C.B.

 

C.B.

 

 

C.B.

 

 

C.B.

 

 

 

 

 

 

 

 

 

30A

 

C.B.

 

30A

 

30A

 

30A

 

 

20A

 

 

20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

50A

 

 

 

11

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

22

 

 

 

 

22

 

 

 

 

0

 

 

 

 

0

 

 

 

 

0

 

 

 

 

44

 

 

 

 

44

 

 

 

 

44

 

 

 

C2-12

00

C2-7

0

14

14

C2-5

FSS

8686

LOP0

 

 

 

0

 

86

0

 

 

 

 

 

 

 

 

C2-2

 

 

 

 

15

 

15

 

 

C2-10

 

 

 

 

15

 

15

 

 

C2-4

 

15

 

 

 

 

 

 

167

 

167

 

 

C2-3

 

SW1

 

15

0

0

17

0

C2-8

 

0

 

 

 

 

 

 

 

 

 

17

 

17

 

LEGEND

BA - BRUSH ASSEMBLY

BCR1 - BATTERY CHARGE RECTIFIER, 10A BCR2 - BATTERY CHARGE RECTIFIER CB1 - 10AMP AUTO RESET BREAKER CB2 - 5AMP AUTO RESET BREAKER

D1 - 600V 12A DIODE

D2, D3 - ENGINE SHUTDOWN DIODE F1 - 10A FUSE

FSS - FUEL SHUT OFF SOLENOID GND - GROUND BAR

I.C.T. - IDLE CONTROL TRANSFORMER IM1 - IGNITION MODULE, CYL. 1

IM2 - IGNITION MODULE, CYL. 2

LOP - LOW OIL PRESSURE

R1 - 25 OHM, 25W RESISTOR

SC - STARTER CONTACTOR

SCR - STARTER CONTACTOR RELAY SM - STARTER MOTOR

SP1 - SPARK PLUG, CYL. 1

SP2 - SPARK PLUG, CYL. 2

 

C2-1

 

18

 

18

17

 

 

 

C2-6

 

13

 

13

15

C2-11

 

 

 

13

 

13

13

 

 

SCR

 

SC

 

 

 

C2-9

16

 

 

16

 

 

17

 

 

D2

IM1

SP1

D3

IM2

SP2

RED

SC

SM

BLACK

BATTERY 12V

SSR - START / STOP RELAY

SW1 - START-RUN-STOP SWITCH

SW2 - IDLE CONTROL SWITCH

TB1, TB2 - TERMINAL BLOCK

=12 VDC SUPPLY

=12 VDC CONTROL

=AC POWER

=GROUND

=IDLE CONTROL TRANSFORMER OUTPUT

The printed circuit board is supplied with AC voltage from Wires 11S and 44S, this voltage /frequency signal is used by the printed circuit board for governor control operation.

When the Idle Control Switch (SW2) is activated to the “ON” position Wire 83 from the printed circuit board will be connected to Wire 0 frame ground. There are two Idle Control Transformers (ICT) that sense current flow off the main power windings. The voltage signal from the ICT’s connect to the Printed Circuit Board via Wires TR1/TR2 and are used for sensing load on the generator. With no-load on the generator there is no current supplied from the ICT’s and the engine will run at a lower RPM. When a load is applied to the generator the ICT’s supply a voltage signal to the Printed Circuit Board and the engine RPM will be increased to running RPM approximately 3600RPM.

Page 25

Page 27
Image 27
Guardian Technologies 5308, 4582 & 4987, 4451 & 4986, 4583 manual = Idle Control Transformer Output