Haier AB212BCBAA, 0010571570 manual When Troubles Occur

Models: 0010571570 AB212BCBAA

1 38
Download 38 pages 54.68 Kb
Page 22
Image 22
When Troubles Occur

When Troubles Occur

Before contacting the commissioned repair center for after-sales service, please check your air conditioner according to the following items.

Symptom

 

Cause

 

 

Solution

The unit does not operate.

The fuse is blown out or the breaker is open.

Change the fuse or close the breaker.

Once the unit operates,

The air inlet or air outlet of indoor or outdo

 

Remove the obstacles.

it stops immediately.

or unit is blocked.

 

 

 

 

The air inlet or air outlet of indoor or outdo

 

 

 

 

or unit is blocked.

 

Remove the obstacles.

 

Improper set temperature

 

Referring to page 8

Abnormal of COOLING

The fan speed is set too low

 

Referring to page 8

Incorrect swing direction

 

Referring to page 9

or HEATING.

The doors or windows are open

 

Close them

 

Direct sunshine

 

Hang the curtain or blinds before

 

 

 

 

windows

 

Too much people in room

 

 

 

 

Too many heat sources in room

 

 

 

Trouble display

 

 

 

 

 

 

 

 

 

Phenomenon of

 

The flashing time of indicator light Indoor control

outdoor unit trouble

 

on outdoor control panel

 

panel indication

The trouble of outdoor ambient

1 (A, B systems indicate together)

 

E3

temperature sensor

 

 

The trouble of outdoor coil

2 (A and B system indicate individually)

E4

temperature sensor

 

Over electric current protection

5 (A and B system indicate individually)

E5

CT wire breaks

 

6 (A and B system indicate individually)

E5

The communication trouble

8 (A and B system indicate individually)

E8

between indoor and outdoor unit

Phenomenon of indoor

Trouble indication on remote

 

Trouble code on wire

unit trouble

 

control type indoor unit

 

control type indoor unit

The trouble of indoor ambient

The compressor indicator light flashes 1

E1

temperature sensor

 

time in 0.2S/time frequency

 

 

 

 

The trouble of indoor coil

 

The compressor indicator light flashes 2

E2

temperature sensor

 

time in 0.2S/time frequency

 

 

 

 

The trouble of outdoor ambient

The compressor indicator light flashes 3

E3

temperature sensor

 

time in 0.2S/time frequency

 

 

 

 

The trouble of outdoor coil

The compressor indicator light flashes 4

E4

temperature sensor

 

time in 0.2S/time frequency

 

 

 

 

The trouble of electric current

The compressor indicator light flashes 5

E5

overload

 

time in 0.2S/time frequency

 

 

 

 

The communication trouble

The compressor indicator light flashes 8

E8

between panel and indoor panel

time in 0.2S/time frequency

 

 

 

The communication trouble

The compressor indicator light flashes 9

 

between indoor panel and

 

time in 0.2S/time frequency

 

E9

outdoor panel

 

 

 

 

 

The trouble of water pump

The compressor indicator light flashes 10

E0

 

 

time in 0.2S/time frequency

 

 

After checking the above items and treating the air conditioner, it still cannot normally work, or find the following troubles occur, please stop the unit and cut off power, then contact the after-sales service worker.

Manual background The fuse and creepage breaker are often blown out;

In Cooling or Dehumidifying operation, there is water leakage;

Manual background Abnormal operation or abnormal sound can be heard.

Manual background The screen on the wire controller shows trouble code (E1, …E0), which

20indicates the air conditioner has trouble.