Installation procedure | Install wire controller | |
|
|
|
1.Remove the upper cover of wire controller | Upper cover of |
wire controller |
The PC board is installed on the back cover of wire controller. When remove the upper cover, pay attention not to damage PC board.
Back cover of wire controller
Switch
Screw hole |
2.Install wire controller
**Drill 2 wall holes according to the position of the 2 screw holes on the back *cover of wire controller, then hit wood in the wall holes. Put the 2 screw holes *on the back cover of wire controller properly to its corresponding wood, then *use wood screws to fix the back cover on the wall.
Note:
Install the back cover of wire controller on the even wall as possible as can. When tightening the wood screw, do not use to tight force, otherwise the wire controller may be damaged.
Switch
Mark | ON | OFF |
| Note: |
|
| |
1 | 3 grades fan speed | 2 grades fan speed |
| When connecting wire, please keep a |
| ||
|
|
|
| certain distance between signal wire and |
| ||
2 | Have rise and drop | No rise and drop |
|
| |||
|
|
|
| electric wire. (over 10mm) |
| ||
3 | Swing | Not Swing |
|
| |||
|
|
|
|
| |||
4 | The collection | The collection |
|
|
|
|
|
|
|
|
| ||||
| temperature of | temperature of |
|
| Dimension of signal wire: |
| |
| main panel | panel |
|
|
| ||
|
|
|
|
|
| ||
|
|
|
|
| Type of wire | Shield wire (4 cords) |
|
Under this series, the switch is set as: |
|
| |||||
| Dimension | 0.33mm2 |
| ||||
1.ON 2. OFF 3. OFF 4.OFF |
|
|
|
| |||
|
|
|
|
3.Indoor unit wire connection |
| The connection between indoor unit | |||||
Connect the terminals (A, B, C, D,) on the wire | |||||||
controller to the terminals on the indoor PC | and wire controller and indoor unit | ||||||
and outdoor unit should use shield | |||||||
panel (A, B, C, D,) respectively. |
| ||||||
| wire. And the two ends of the shield | ||||||
|
|
| |||||
Arrange wire from this part |
| wire | should | be | grounded, | ||
AB | CD |
| otherwise, the disturbance will | ||||
| Back cover |
| cause unit abnormal operation. | ||||
|
|
|
|
|
| ||
| wire controller | Upper cover | Shield wire | ||||
|
| of wire |
| ||||
|
| controller | Grounded |
| Grounded |
Note:
Confirm the connection part of terminals is firm and will not touch shield wire.
4.Cover the wire controller upper cover
Pay attention not to press the connection wire.
Note: Do not touch PC board by hand.
30