Haier AB212BCBAA, 0010571570 manual Test run, Installation procedure

Models: 0010571570 AB212BCBAA

1 38
Download 38 pages 54.68 Kb
Page 38
Image 38
Test run

Installation procedure

Other instruction 1.Power supply

Manual background The air conditioner must use a special power circuit and special air switch (40A). The wiring should be done by a qualified electrician according to the wiring rules specified by national standard

An creepage breaker should be installed.

Manual background The grounding wire and null wire of receptacle should be strictly separated. Manual background It is incorrect to connect the null wire with grounding wire.

Manual background The connection method of power cord is Y connection. If the power cable is damaged, in order to avoid danger, it must be replaced by the manufacturer or its specified repair center of the same qualified worker.

2. Cut and flaring method

Use pipe cutter to cut the pipe, the burrs must be removed.

After inserting the flarer, perform flared nut.

A

Flarer

 

Flaring dimensions as follows:

Connent pipe

Pipe diameter

Dimension A (mm)

Liquid pipe

9.52mm (3/8")

1.0-1.2

Gas pipe

19.05mm (3/4")

1.4-2.2

Correct

Incorr

Slant Broken Burrs Uncompleted Too long

Test run

The following items must be noticed carefully during installation. After finishing installation, performing checking.

After installing the refrigerant pipe, drain hose and electric wire properly, perform test run to ensure the system not have trouble.

Perform test run before installing decorative panel

(1)Open the stop valve of gas pipe. (2)Open the stop valve of liquid pipe.

(3)Use remote controller to set to COOLING operation, press ON/OFF button to start operation.

(4)After finishing operation, cut off the general power supply.

Perform test run after installing decorative panel

(1)Open the stop valve of gas pipe.

(2)Open the stop valve of liquid pipe.

Note: The wiring diagram of this model is pasted inside of the unit.

36

Page 38