When connecting the cable after installing the indoor unit

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

When connecting the cable after installing the indoor unit

1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed.

2. Pull out the cable on the front side, and connect the cable making a loop.

When connecting the cable before installing the indoor unit

When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side.

Indoor unit Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.

Outdoor unit Pull the cable slightly to make sure the cables have been properly inserted and tightened.

Manual background After the cable connection, never fail to fasten the connected cable with the wiring cover.

Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect.

1.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F.

2.If the fuse on PC board is broken please change it with the type of T.3.15A/250V.

3.The wiring method should be in line with the local wiring standard.

4.After installation, the power plug should be easily reached.

YEL/GRNWHT

RED

BLK

 

BLK

RED

WHT

 

 

YEL/GRN

Indoor unit

 

Outdoor unit