Haier HSU-09HS03/R2DB Installation of Outdoor Unit, Connection of Pipes, Attaching Drain-Elbow

Models: HSU-12HS03/R2DB HSU-09HS03/R2DB

1 65
Download 65 pages 35 Kb
Page 62
Image 62
Outdoor Unit

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

Outdoor Unit

1 Installation of Outdoor Unit

Install according to Drawing for the installation of indoor and outdoor units

2 Connection of Pipes

1 Installation of Outdoor Unit To bend a pipe, give the roundness as large as possible not to crush the pipe, and the bending radius should be 30 to 40 mm or longer.

2 Connection of Pipes Connecting the pipe of gas side first make working easier.

3 Connection The connection pipe is specialized for R410A.

4 Attaching Drain-Elbow The max length of connection pipe of 12 series is 15m and the max length of 07,09 series is 7m. Manual background The max vertical distance between the indoor unit and the outdoor unit is 5m

Half union

 

 

Flare nut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spanner

Torque wrench

Forced fastening without careful centering may damage the threads and cause a leakage of gas.

Pipe Diameter( )

Fastening Torque

 

 

 

Liquid Side 6.35mm(1/4")

18N.m

 

 

Gas Side 6.35mm(3/8")

42N.m

 

 

Gas Side 12.7mm(1/2")

55N.m

 

 

 

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.

The standard pipe length is 5m, If it is over 5m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant.

3 Connection

Manual background Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws

Manual background Insert the cable according to terminal number in the same manner as the indoor unit.

4 Attaching Drain-Elbow

Manual background If the drain-elbow is used, please attach it as figure.

Note: Only for heat pump unit.

Manual background If wiring is not correct, proper operation can not be carried out and controller may be damaged.

Manual background Fix the cable with a clamp.

Drain hose

62

Page 62
Image 62
Haier HSU-09HS03/R2DB Installation of Outdoor Unit, Connection of Pipes, Attaching Drain-Elbow, Domestic Air Conditioner