Haier HSU-12HS03/R2DB Domestic Air Conditioner, Specification, 3440460-3920W, 3820700-5100W

Models: HSU-12HS03/R2DB HSU-09HS03/R2DB

1 65
Download 65 pages 35 Kb
Page 7
Image 7
Specification:

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

Specification:

Model:

(HSU-12HS03/R2(DB))

Appearance color

White/White

 

(indoor/outdoor):

 

 

 

 

 

 

 

 

Cooling capacity:

3440(460-3920)W

Heating capacity:

3820(700-5100)W

 

 

 

 

 

 

Cooling coefficient:

3.21

Heating coefficient:

3.00

 

Cooling power input:

1070(185-1420)W

Heating power input:

1270(666-1520)W

Moisture removal

1.5X10-3m3/h

Frequency range

12~120 Hz

Operating voltage range

1PH, 220-230V~,50Hz

Refrigerant type

R410A

Operating temp. range

-7OC-43OC

Air sending angle/distance

60O

 

 

 

 

 

 

Variation of temp. adjust

 

+1OC

Fan type/quantity

Cross flow fan(indoor unit)

 

Axial fan(outdoor unit)

 

 

 

 

 

Climate type:

T1

Class of electric shock protection:

I

Indoor unit noise

42/38/35dB(A)

outdoor unit noise

56/48dB(A)

(cooling)

 

 

(cooling)

 

 

Indoor unit noise

42/38/35dB(A)

outdoor unit noise

58/48dB(A)

(heating)

(heating)

 

 

 

 

 

 

net dimensions

760x182x285mm

net dimensions

780 x245x540mm

 

 

 

 

 

 

Packaging dimensions

837 x282x312 mm

Packaging dimensions

908x342x619mm

(indoor unit)

(outdoor unit)

 

 

 

 

weight(indoor unit )

8.6/10.8(net/gross)kg

Piling layers for indoor/outdoor

8/4

 

 

 

 

unit

 

 

Max. mounting height

15m

Outdoor unit net/gross weights:

33/36(net/gross) kg

difference:

 

 

 

 

 

 

 

 

 

Refrigerant charge

R410A 940g

Current entering side

indoor

(indoor/outdoor)

Frequency of filter cleaning

Once/2 weeks

Max. refrigerant charge

-------------

 

 

 

 

 

 

 

Compressor model

C-6RZ092H1A

Compressor manufacturer

SANYO

Compressor oil charge

320ml

Compressor protector type

INTERNAL

Maxi. length of connecting

15m

model of 4-way valve:

-------------

 

pipe:

 

Cap. tube type muffle

TP2Y copper tube

Length/diameter of drain hose

2000mm/O16mm

model:

 

 

 

 

 

 

Fan speed: (r/min)

1300(h)/1250(c)1100/950 (indoor)

Type/size of evaporator and

Internal treaded pipe

 

800/500 (outdoor)

condenser

O7/O7mm

Max. operating pressure at

4.15MPa

Max. operating pressure at cool

4.15MPa

side:

warm side:

 

 

 

 

cut-off valve:

1/4”,1/2”

Appearance features

Indoor unit:Plastic

Outdoor unit: Metal

 

 

 

 

 

 

 

 

 

 