Haier HSU-09HS03/R2DB Domestic Air Conditioner, Heating, Cooling, moisture, removing

Models: HSU-12HS03/R2DB HSU-09HS03/R2DB

1 65
Download 65 pages 35 Kb
Page 26
Image 26
Heating

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

The maximum frequency value refers to the max value listed above.

The maximum and minimum values for cooling and heating are the maximum and minimum values for correspondent items.

2.4.7 Controlled frequency for the same level

The indicated frequency when a level remains unchanged after the compressor operates with the same frequency for 3 minutes.

The timing will start again when there is a different frequency input. If the temperature level remains unchanged for 3 minutes, the indicated frequency will change again (add FQUPH or FQUPL)

Controlling form for the same level

 

 

Levels of temperature change

 

 

A B

C

D

E

F

G

H

Heating

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

moisture

 

 

 

 

 

 

removing

 

 

 

 

 

 

2-4-8. Select the wind volume when it is set automatic

When the wind volume is automatic, it can be switched between strong, medium and weak according to the temperature adjusting levels.

Wind volume under the automatic wind volume mode

 

 

 

Temperature adjusting levels

 

 

 

A

B

C

D

E

F

G

H

I

Heating

Str

Stro

Stro

Stro

Stron

Med

Wea

Wea

SLO

 

on

ng

ng

ng

g

ium

k

k

 

 

g

 

 

 

 

 

 

 

 

cooling

 

Stro

Stro

Stro

Medi

Med

Wea

Wea

Weak

 

 

ng

ng

ng

um

ium

k

k

 

Moisture

 

Stro

Med

Med

Medi

Wea

Wea

SLO

SLO

removing

 

ng

ium

ium

um

k

k

 

 

2-5. Frost removing

Under the intensive-running protection mode, the protection control will be in priority

The compressor does not stop

Under heating operation mode, the outdoor unit sends a frost-removing signal (I21=10) and the indoor unit will start the frost-removing control until the outdoor unit transmits the signal to end the frost-removing. Then the indoor unit starts the heating operation, indication levels and wind volume control will operate following the heating temperature levels.

2-6. Wind volume limit

. When the compressor is working and the max setting for indoor blower fan is medium , the upper limit of indicated frequency is as follows:

26

Page 26
Image 26
Haier HSU-09HS03/R2DB, HSU-12HS03/R2DB service manual Domestic Air Conditioner, Heating, Cooling, moisture, removing