Haier HSU-09HS03/R2DB On Drainage, Check for Installation and Test Run, Power Source Installation

Models: HSU-12HS03/R2DB HSU-09HS03/R2DB

1 65
Download 65 pages 35 Kb
Page 64
Image 64
1 Power Source Installation

Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

1 Power Source Installation

2 Cutting and Flaring Work of Piping The power source must be exclusively used for air conditioner. (Over 10A)

3 On Drainage In the case of installing an air conditioner in a moist place. please install an earth leakage breaker.

Check for Installation and Test Run For installation in other places, use a circuit breaker as far as possible.

2 Cutting and Flaring Work of Piping

Check Items for Test Run Pipe cutting is carried out with a pipe cutter and burs must be removed.

Manual background After inserting the flare nut, flaring work is carried out.

Flare tooling die

1.Cut pipe

2.Remove burs

 

Flare tool for R410A

Conventional flare tool

 

Clutch-type

clutch-type(Rigid-type)

Wing-nut type (Imperial-type)

 

 

 

 

 

0~0.5mm

1.0~1.5mm

1.5~2.0mm

 

 

 

 

3.Insert the flare nut

4.Flare pipe

Correct

Incorrect

 

Lean

Damage of flare Crack

Partial Too outside

3 On Drainage

Manual background Please install the drain hose so as to be downward slope without fail. Manual background Please don't do the drainage as shown below.

It becomes high midway.

The end is immersed

It waves.

 

in water.

 

Less than 5cm

The gap with the ground is too small.

There is the bad smell from a ditch.

Manual background Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor.

Manual background In case that the attached drain hose is in a room, please apply heat insulation to it without fail.

Check for Installation and Test Run

Manual background Please kindly explain to our customers how to operate through the instructio manual.

Check Items for Test Run

Manual backgroundManual background Gas leak from pipe connecting?

Manual backgroundManual background Heat insulation of pipe connecting?

Manual backgroundManual background Are the connecting wirings of indoor and outdoor firmly inserted

to the terminal block?

Manual backgroundManual background Is the connecting wiring of indoor and outdoor firmly fixed?

Manual backgroundManual background Put check mark Manual background in boxes

Manual backgroundManual background Is drainage securely carried out?

Manual backgroundManual background Is the earth line securely connected?

Manual backgroundManual background Is the indoor unit securely fixed?

Manual backgroundManual background Is power source voltage abided by the code?

Manual backgroundManual background Is there any noise? 64

Manual backgroundManual background Is the lamp normally lighting?

Manual backgroundManual background Are cooling and heating(when

in heat pump) performed normally?

Manual backgroundManual background Is the operation of room temperature regulator normal?

Page 64
Image 64
Haier HSU-09HS03/R2DB, HSU-12HS03/R2DB On Drainage, Check for Installation and Test Run, Power Source Installation