Domestic Air Conditioner

HSU-12HS03/R2(DB)

Model: HSU-09HS03/R2(DB)

Refer to the temperature level control function

 

3-1-4. Frost-removing operation

. The blower stops after 20 seconds

. When receiving the I21=11 signal from the outdoor unit in the heat frost-removing mode, warm boot will be done according to the hear exchange sensor. The wind volume control is the same with 3.1.1

When the frost-removing process if over, if the compressor is on,the wind volume control will be warm-booted; if the compressor if switched off, the wind volume will be weak.

3-2 cooling running

. The wind volume can be set to strong, medium and weak.

Automatica wind volume function will decide the wind volume according to the temperature

Picture3.3

3-3. Moisture removing running

3-3-1. Compressor off, idle mode for 3 minutes

. The blower fan stops as the compressor stops

. The operation is wead after 3 minutes’ idle mode

. After 3 minutes’ ilde mode, the compressor is on.

3-3-2. Compressors on

The compressor operates as the set wind volume when the wind volume is set to be strong, medium or weak

. The wind volume is decided according to the temperature adjusting when the wind volume is set to be automatic.

Picture 3.4

Moisture removing running

Level H

3minutes idle mode

CompressorOFF

 

Setting slightly weak OFF

weak

weak

setting

4.Powerful Running

 

 

 

. Powerful running for 15 minutes

 

 

 

. The running stops or ends the powerful running after 15 minutes

. The mode switch ends the powerful running

. Enter into the silent mode, normal running mode or timed switching on mode to end the powerful running

. When in automatic mode, there are powerful and silent functions for your choice. When the main unit is in cooling mode, it operates with powerful cooling or silent cooling. When the main unit is in heating mode, it operates with powerful heating or silent heathing. When the main unit is in wind-sending mode, there are no powerful or silent modes.

4-0-1. Powerful heating

29

Page 29
Image 29
Haier HSU-12HS03/R2DB, HSU-09HS03/R2DB service manual Refer to the temperature level control function