Haier HSU-12HSA03/R2(DB) manual Control the temperature the area, Deviation, Compressor operating

Models: HSU-12HSA03/R2(DB) HSU-09HSA03/R2(DB)

1 90
Download 90 pages 45.19 Kb
Page 11
Image 11
2.4 Control the temperature the area

 

 

Haier air conditioner

Edition: 20070116

 

 

 

 

 

 

 

Mode

Corrected contents

Corrected variable

Corrected

 

 

parameter

 

 

 

 

 

 

 

 

Correct the operating mode

ETBL0

4.67

 

 

 

 

 

 

 

 

 

Correct forced operating mode

ETBL1

6

 

 

 

 

 

 

 

 

Heat

When the air capacity is low to

ETBL2

4.67

 

 

 

correct it

 

 

 

 

 

 

 

 

When the air capacity is low to

ETBL3

4.67

 

 

 

correct it

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool and

Correct the operating mode

ETBL4

-0.33

 

 

dry mode

 

 

 

 

 

Correct the forced operating mode

ETBL5

-4

 

2.4 Control the temperature the area

2.4.1 Deviation

Calculation the deviation of the temperature area, as following:

Heat: E= (remote control preset temperature + corrected value)-room temperature

Cool and dry: E=room temperature - (remote control preset temperature+ corrected value)

2.4.2 Compressor OFF OFF When E is negative and E>?T:

 

Heat

 

Cool

 

 

 

 

 

 

?T

TCHAHL

0.67

TCHACL

 

0.33

After ?T variation

TCHAHH

0.67

TCHACH

 

1

?T variation condition

When the system is start to operate, E=3.0

,

The compressor will be stopped after detected continuously for 120 seconds.

After operation starts, when compressor turns off at the first time, based on the above conditions, the unit should operate according to ?T variable data. Between the time when compressor is off and restarts, the unit should operate on ?T starting data (Except dry) and operating mode is transferring. (Except the case that waiting unit is off). Compressor starts when the wrap E is larger than –?T. When compressor is operating and the set temperature by the remote control changes in the orientation that compressor is off, in addition, it is below –?T, compressor will be off.

2.4.3 Compressor operating

During the time when compressor is off, after waiting for 3 minutes, the deviation E is much larger

than- T +0.67 , compressor will start to operate.

2.4.4 DASH operation

When the system starts to operate or to switch the operation mode (except compressor first to off and then to on), when the compressor is on, the system will indicate the maximum frequency satisfied condition as following:

Cool

deviate to 0

Dry

deviate to G area

Heat

deviate to F area

 

- 11 -

Page 11
Image 11