Haier air conditioner

Edition: 20070116

F21: Frost-removing temperature sensor failure

CN10

F25: Exhaust temperature sensor failure

CN11

F6: Ambient temperature sensor failure

CN9

Firstly check whether Terminal CN10 (or CN11, or CN9) on the out door mainboard contact well or not?

Yes

Pull the sensor out of the mainboard

1)Measure the value of resistance between its two jumpers

2)Measure the temperature at the room temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged or not?

No

The Outdoor PCB is broken

Replace with new outdoor PCB

No

Yes

Pull out the terminals on the outdoor mainboard and reinsert them.

Sensor is broken

Replace with a new sensor

- 43 -

Page 43
Image 43
Haier HSU-12HSA03/R2(DB), HSU-09HSA03/R2(DB) manual CN9