Haier air conditioner | Edition: 20070116 |
4. Thermistor resistance chart
Room temperature sensor
Temp. ( ) | R (KO) | Power Input (V) |
281.34 | 0.33 | |
263.56 | 0.35 | |
|
|
|
247.84 | 0.37 | |
231.66 | 0.40 | |
|
|
|
217.35 | 0.42 | |
204.02 | 0.45 | |
191.61 | 0.47 | |
180.04 | 0.50 | |
169.24 | 0.53 | |
159.17 | 0.56 | |
149.77 | 0.59 | |
|
|
|
140.99 | 0.62 | |
132.78 | 0.65 | |
|
|
|
126.11 | 0.69 | |
117.93 | 0.73 | |
|
|
|
111.22 | 0.76 | |
104.93 | 0.80 | |
98.04 | 0.84 | |
93.52 | 0.88 | |
88.35 | 0.92 | |
0 | 83.50 | 0.97 |
|
|
|
1 | 78.94 | 1.01 |
2 | 74.67 | 1.06 |
|
|
|
3 | 70.65 | 1.10 |
4 | 66.88 | 1.15 |
5 | 63.33 | 1.20 |
|
|
|
6 | 60.00 | 1.25 |
7 | 56.88 | 1.00 |
8 | 53.91 | 1.35 |
9 | 51.15 | 1.41 |
10 | 48.51 | 1.46 |
11 | 46.04 | 1.51 |
|
|
|
12 | 43.72 | 1.57 |
13 | 41.52 | 1.63 |
|
|
|
14 | 39.45 | 1.68 |
15 | 37.50 | 1.74 |
|
|
|
16 | 35.66 | 1.80 |
17 | 33.92 | 1.85 |
18 | 32.27 | 1.91 |
| - 30 - |
|