Setting position range

Haier air conditioner

Edition: 20070116

measure standard position for enter cool /heat mode. When operate starting, alarming to keep current position. Received ventilated direction command delay 1s processing

Setting position range

Cool/dry:

Pulse scope 45 degree

Heat:

Pulse scope 60degree

During operating in closed cycle, it will move into open direction.

Swing-blade operating stop, keep the last output phase of excitation (1 phase); when unit operating stop (all close), all of 4 phase close.

In the set range, back and forth move, the acting is foreign to ON/OFF of temperature sensor. Cool/dry: Pulse scope 45degree.

Heat: Pulse scope 60degree.

At the both points waiting for 0.5s to return.

Received signal of stop operating or change direction, cancel swing mode. During swing, appears alarm, the swing will continues.

During start operating, confirm adjustment position that is foreign to on/off of temperature sensor When stop, move from current position to full close.

When switch mode, based on the position of panel send.

Under fixed position mode, alarm position keeps in the current position.

During heat swing, when switch to cool mode by the received signal, its acting position based on indicator of remote control.

Adjust position based on the received contents, no delay 1s.

Up/down swing

 

Full off

swing angle in cool

60º

 

 

1(cool normal position

make an angle

 

 

of 10º with horizontal)

 

 

Position 2

make an angle of 25º with

 

 

 

horizontal)

 

Position 3

make an angle of 40º with

 

 

 

horizontal)

Position 4 make an angle of 55º with horizontal) swing angle

 

 

in heat 45º

 

Full opening position 5

normal position in heat mode make an angle of

 

 

 

70ºwith horizontal)

Reference position

 

 

 

 

Swing angle in the cool and dry mode 45°

 

 

 

Swing angle in the heat mode

60°

 

 

 