Haier HSU-09HSA03/R2(DB) manual Rating operating, rating cool, middle capacity, min capacity cool

Models: HSU-12HSA03/R2(DB) HSU-09HSA03/R2(DB)

1 90
Download 90 pages 45.19 Kb
Page 24
Image 24
2. Rating operating

Haier air conditioner

Edition: 20070116

2. Rating operating

 

rating cool:

 

a. G code enter condition high speed cool set temp. is 16

press temperature “-” key and set key

together, enter mode after resound 2 times.

 

b. then operate as following:

Enter rated frequency operation mode; panel shown cool status; in communication rated shown.

c. Exit condition Exit rated operate mode and enter remote control set status after received remote control signal.

middle capacity:

a. G code enter conditions High fan cool, set temp. is 16 , press 4 times continuantly in 7s Enter rated frequency operation; Panel show cool status; have ration in communication.

Reso Enter rated frequency operation; Panel show cool status; have ration in communication. Resound 5 times.

b. then operating as following: enter middle capacity rated frequency operating;

c. Exit condition Exit rated operate mode and enter remote control set status after received remote control signal.

min capacity cool

a. G code enters condition: remote control high fan cool, set temp. is 16 , press 8 times continuantly in 7s resound 7 times.

b. then operating as following: enter min capacity rated frequency operating; panel show cool status; have ration in communication.

Enter rated frequency operation; Panel show cool status; have ration in communication.

c. Exit condition Exit rated operate mode and

 

rated heat: rating heat

 

a. G code enter condition high speed cool set temp. is 16

press temperature “-” key and set key

together, enter mode after resound 2 times.

 

b. Then operation as following program:

 

Panel show heat status; have ration in communication.

 

Enter rated frequency operation; Panel show cool status; have ration in communication. c. Exit condition: enter remote control set status after received remote control signel.

middle capacity heat:

a. G code enters condition Remote control high fan heat, set temp. is 30.7 , press 4 times

continuantly in 7s

resound 7 times.

b. Then operation as following program: panel show cool status; have ration in communication.

Enter rated frequency operation; Panel show cool status; have ration in communication.

c. Exit condition

Exit rated operate mode and enter remote control set status after received remote

control signal.

 

min capacity heat:

a. G code enters condition Remote control high fan heat, set temp. is 30 , press 8 times continuantly

- 24 -

Page 24
Image 24
Haier HSU-09HSA03/R2(DB) manual Rating operating, rating cool, middle capacity, min capacity cool, rated heat: rating heat