|
|
| Haier air conditioner |
|
| Edition: 20070116 | ||
|
| 256 |
|
| 256 |
|
| 319.5 |
140 | 500 | 140 |
|
|
| 113.5 | 583 | 113.5 |
140 | 500 | 140 |
|
|
| |||
|
|
|
|
|
| |||
Floor fixing dimensions | Floor fixing dimensions | Floor fixing dimensions | ||||||
of the outdoor unit |
| of the outdoor unit |
| of the outdoor unit | ||||
|
| (Unit:mm) |
| |||||
(Unit:mm) |
| (Unit:mm) |
|
|
| |||
|
|
|
|
|
| |||
| ||||||||
|
|
|
Fixing of outdoor unit
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a
Indoor Unit | Selection of Installation Place Outdoor Unit |
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked is available as illustrated in the above figure.
Power Source
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
The thickness of the pipe must be 0.8mm at least.
| For 09 | For 12,18,22 |
|
|
|
Liquid pipe | 6.35mm(1/4") | 6.35mm(1/4") |
|
|
|
Gas pipe | 9.52mm(3/8") | 12.7mm(1/2") |
|
|
|
- 83-