Haier HSU-09HSA03/R2(DB) Room temperature sensor failure, Heat-exchangesensor failure, No Yes

Models: HSU-12HSA03/R2(DB) HSU-09HSA03/R2(DB)

1 90
Download 90 pages 45.19 Kb
Page 42
Image 42
Room temperature sensor failure

 

Haier air conditioner

Edition: 20070116

E1:

Room temperature sensor failure

CN8

E2:

Heat-exchange sensor failure

 

Firstly check whether Terminal CN8(CN6) on the indoor mainboard contact well or not?

Yes

Pull the sensor out of the mainboard

1)Measure the value of resistance between its two jumpers

2)Measure the temperature at the room temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged or not?

No

The Indoor PCB is broken Replace with new indoor PCB

No

Yes

Pull out the terminals on the indoor mainboard and reinsert them.

Sensor is broken

Replace with new indoor PCB

- 42-

Page 42
Image 42
Haier HSU-09HSA03/R2(DB) manual Room temperature sensor failure, Heat-exchangesensor failure, Haier air conditioner, No Yes