5. Trouble shooting

 

Haier air conditioner

Edition: 20070116

5. Trouble shooting

 

 

 

Indoor

Outdoor

 

Possible Reasons

 

E1

/

1)Room-temperature sensor

 

2) Indoor PCB

 

 

 

 

 

 

 

 

E2

/

1)Heat-exchange sensor

 

2)Indoor PCB

 

 

 

 

 

 

 

 

 

 

With the malfunction, LED1

 

 

 

F21

on the outdoor mainboard

1) Defrosting temperature sensor

 

blinks 10 times at frequency

2) Outdoor PCB

 

 

 

 

of 1 Hz

 

 

 

 

With the malfunction, LED1

 

 

 

F25

on the outdoor mainboard

1) Exhaust temperature sensor

 

blinks 13 times at frequency

2) Outdoor PCB

 

 

 

 

of 1 Hz

 

 

 

 

 

 

 

 

 

With the malfunction, LED1

 

 

 

 

on the outdoor mainboard

1) Ambient

temperature sensor

 

F6

blinks once at 12 times of 1

 

2) Outdoor PCB

 

 

Hz and interval of 2 seconds

 

 

 

 

 

 

or so.

 

 

 

 

 

 

 

 

 

1)The outdoor mainboard needs

 

 

 

dehumidification

 

 

 

2)The outdoor mainboard needs

 

 

With the malfunction, LED1

dehumidification

 

 

3)The linking cable between the indoor and

 

E7

on the outdoor mainboard

 

outdoor units is not well connected or the

 

 

blinks 15 times

 

 

core wires are not well insulated 4)The

 

 

 

 

 

 

indoor PCB might be broken

 

 

 

5)The outdoor PCB might be broken

 

 

 

6)The SPDU might be broken

 

 

 

 

 

 

With the malfunction, LED1

1) The wiring of compressor is incorrect or

 

F11

on the outdoor mainboard

the connection is poor

 

blinks17or18 times at

2)The SPDU might be broken

 

 

 

 

frequency of 1 Hz

3) Compressor might be damaged.

 

 

 

 

 

 

 

1) The cryogen may have been leaked

 

 

With the malfunction, LED1

during installation, or there may be leakage

 

F4

on the outdoor mainboard

in the piping system.

 

blinks 8 times at frequency

2)Exhaust temperature sensor is broken

 

 

 

 

of 1 Hz

3) The outdoor mainboard is damaged and

 

 

 

needs be replaced

 

 

 

 

 

 

 

-40 -

 

 

 