Haier HSU-12HSA03/R2(DB) manual 6.5Sensible cooling value-temperaturecurves, HSU-09HSA03/R2DB

Models: HSU-12HSA03/R2(DB) HSU-09HSA03/R2(DB)

1 90
Download 90 pages 45.19 Kb
Page 71
Image 71
6.5Sensible cooling value-temperature curves

Haier air conditioner

Edition: 20070116

6.5Sensible cooling value-temperature curves

HSU-09HSA03/R2(DB)

Sensible cooling value - Temperature table

Indoor temp.

 

 

Outdoor temp. (Humidity 46%)

 

 

DB/WB

18

20

25

32

35

40

43

46

18/12

1885

1783

1720

1647

1489

1400

1315

1236

18/14

1917

1866

1800

1720

1545

1489

1400

1310

20/15

1982

1920

1845

1764

1634

1536

1408

1315

 

 

 

 

 

 

 

 

 

22/16

2061

1969

1935

1870

1691

1562

1445

1347

 

 

 

 

 

 

 

 

 

25/18

2137

2066

2003

1961

1774

1667

1491

1366

27/19

2232

2132

2063

2020

1885

1713

1570

1459

 

 

 

 

 

 

 

 

 

30/22

2320

2261

2192

2147

1941

1769

1630

1486

 

 

 

 

 

 

 

 

 

32/23

2430

2348

2260

2181

2051

1834

1699

1562

32/24

2501

2404

2302

2218

2056

1920

1723

1574

 

 

 

 

 

 

 

 

 

 

 

 

 