Haier HSU-09HSA03/R2(DB), HSU-12HSA03/R2(DB) manual Indoor unit

Models: HSU-12HSA03/R2(DB) HSU-09HSA03/R2(DB)

1 90
Download 90 pages 45.19 Kb
Page 84
Image 84
Indoor unit

Haier air conditioner

Edition: 20070116

Indoor unit

1.Fitting of the Mounting Plate and Positioning of the wall Hole

When the mounting plate is first fixed

1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.

2.Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.

3.Find the wall hole location A using a measuring tape

B=70mm

A=180mm

35

Find the level position

When the mounting plate is fixed side bar and lintel

Manual background Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten

the plate to the fixed mounting bar.

Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.

2.Making a Hole on the Wall and Fitting the Piping Hole Cover

Manual background Make a hole of B mm in diameter, slightly descending to outside the wall.

Manual background Install piping hole cover and seal it off with putty after installation

Indoor side Wall hole

B

Outdoor side

Thickness of wall

(Section of wall hole) Manual background Piping hole pipe

-84 -

Page 84
Image 84
Haier HSU-09HSA03/R2(DB), HSU-12HSA03/R2(DB) manual Indoor unit