Serial Triggering
This provides a means of sending a serial trigger command to start and stop decoding. When this feature is turned Off, the Imager will not respond to serial trigger commands. When serial triggering is turned On, the Imager requires a serial trigger character to activate scanning and decoding. The unit continues to scan and decode until the Trigger Off character turns off the scanner, a time out occurs, or a bar code is decoded.
On the "Decimal to Hex to ASCII Conversion Chart" on page
When Serial Triggering is On, the default Trigger On decimal character is 18 (hex 12, DC2), and the default Trigger Off decimal character is 20 (hex 14, DC4).
On | * Off |
Trigger On ‡ | Trigger Off ‡ |
*Trigger Defaults
Note: ‡ A one to three digit decimal number and Save are required after reading this programming symbol. See "Decimal to Hex to ASCII Conversion Chart" on page
2 - 14